Herunterladen Inhalt Inhalt Diese Seite drucken

Additional Information - Elcometer 506 Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33

14 ADDITIONAL INFORMATION

Dolly Diameter
Scale Range
Operating Range
(Certified)
Scale Resolution
Accuracy
Power Supply
(Digital Gauge only)
Instrument Weight
Kit Weight
Instrument Length
Actuator Height
Can be used in accordance with:
AS/NZS 1580.408.5, ASTM D4541, ASTM D7234, BS 1881-207, DIN 1048, EN 12636, EN 13144,
EN 1542, ISO 16276-1, ISO 4624, NF T30-606
Note: The Elcometer 506 Adhesion Tester is a Type IV adhesion tester as defined by ASTM D4541.
www.elcometer.com
14.2mm
0 - 52MPa (0 - 7600psi)
Analogue: 6 - 46MPa
(880 - 6680psi)
Digital:
4 - 50MPa
(580 - 7260psi)
Analogue: 0.1MPa (10psi)
Digital:
0.01MPa (1psi)
2 x AA alkaline dry batteries (rechargeable batteries can be used)
1.8kg (4lb)
n/a
290mm (11.5")
85mm (3.4")
(14.2mm skirt fitted)
20mm
0 - 26MPa (0 - 3800psi)
Analogue: 3 - 23MPa
(440 - 3340psi)
Digital:
2 - 25MPa
(290 - 3630psi)
Analogue: 0.1MPa (10psi) Analogue: 0.05MPa (5psi)
Digital:
0.01MPa (1psi) Digital:
±1% of full scale
1.8kg (4lb)
4kg (8.8lb)
290mm (11.5")
85mm (3.4")
(20mm skirt fitted)
50mm
0 - 4.2MPa (0 - 610psi)
Analogue: 0.5 - 3.7MPa
(70 - 535psi)
Digital:
0.3 - 4MPa
(45 - 580psi)
0.01MPa (1psi)
2.0kg (4.4lb)
5.2kg (11.5lb)
290mm (11.5")
110mm (4.3")
(50mm skirt fitted)
R
14
Inhaltsverzeichnis
loading