Herunterladen Inhalt Inhalt Diese Seite drucken

Zodiac VORTEX 3 Montage- Und Gebrauchsanleitung Seite 23

Vorschau ausblenden Andere Handbücher für VORTEX 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38
2-Notice CO ANG.qxd
13/09/10
The programme I and programme II indicators flash alternately:
Your cleaner has encountered a problem or a defect during its operation.
Disconnect the power supply and wait 20 seconds before reconnecting the control box.
Check that the cable is correctly connected to the control box.
Check that no debris impedes the rotation of the brushes and/or the propeller.
Clean the filter.
Start a new cleaning programme.
If the problem continues contact your retailer.
Troubleshooting on flashing lights:
The flashing light indicates to the customer different issues on the control unit and on the cleaner.
These indications are not necessarily major issues.
To remove the flashing light, press the
If the cleaner runs fine during around 5 minutes, it was a minor troubleshooting.
If the flashing light persists, check the cleaner with following procedure first.
After this check, if the flashing light persists, please contact your retailer.
In any case, don't open the control unit.
Issue: The flashing lights appears just after to start the cleaner (< 20 seconds).
Solution:
Ensure the floating cable is plugged to the control unit.
Unplug the floating cable from the control unit and plug it again properly.
Ensure the cleaner is well submerged.
Then, start a new cycle and ensure the impeller turns (flow water behind the cleaner) and the
2 wheels turn.
If the impeller doesn't turn, check if there is some debris around the impeller.
Procedure:
Ensure that the control unit cable has been disconnected from the electrical outlet or that the
floating cable has been disconnected from the control unit.
Lift the cover. Remove the filter.
Unscrew the screw of the grid
Push the edges of the grid (17-2) and in the same time lift the grid (17-3).
Lift the extremity of the flow outlet (17-4) and the same time pull it outside (17-5).
Clean the impeller or the flow outlet and re-assembly all the parts properly.
Check the cleaner again in the pool: if the impeller doesn't' turn please contact your retailer.
If one wheel or two wheels don't turn, please contact your retailer.
Issue: The flashing lights appears during the cycle.
Solution:
If the cleaner sucks air during 60 seconds, the flashing light appears. Submerged the cleaner
in the pool again.
9:12
Page 23
(Diagram
button. Then start a new cycle:
17-1).
23
Diagram 17

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vortex 4

Inhaltsverzeichnis