N o s e A s s e m b l i e s
F i t t i n g I n s t r u c t i o n s
The air supply must be disconnected when fitting or removing nose assemblies.
Item numbers in bold refer to nose assembly components in all 3 nose tip tables.
Lightly coat jaws 4 with Moly lithium grease*.
Drop jaws 4 into jaw housing 3.
Insert jaw spreader 5 into jaw housing 3.
Locate buffer 6 on jaw spreader 5.
Locate spring 7 onto jaw spreader 5.
Fit locking ring 8 onto the jaw spreader housing of the tool.
Holding tool pointing down, screw the assembled jaw housing onto the jaw spreader housing and tighten with spanner.
Screw the nose tip into nose casing 1 and tighten with spanner*.
Place nose casing 1 over jaw housing 3 and screw onto the tool, tightening with spanner*
S e r v i c i n g I n s t r u c t i o n s
Nose assemblies should be serviced at weekly intervals. You should hold some stock of all internal components of the nose assembly
and nose tips as they will need regular replacement.
Remove the nose equipment using the reverse procedure to the 'Fitting Instructions'.
Any worn or damaged part should be replaced.
Clean and check wear on jaws.
Ensure that the jaw spreader is not distorted.
Check spring 7 is not distorted.
Assemble according to fitting instructions above.
Item numbers in bold refer to the illustrations on pages 8 and 10.
* Item included in the G2-s service kit. For complete list see page 18.