Herunterladen Inhalt Inhalt Diese Seite drucken

List Of Parts - cleanAIR CHEMICAL 2F Gebrauchsanweisung

Motorisierte atemwege
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
Fault
Probable cause
Battery discharge
(check : the unit starts working
after replacing the battery with
The unit does not work at all
another functional battery)
Fault of motor, electronics or
charging connector
Blocked air-hose or air channel.
Air leakage.
The unit does not supply satisfactory
amount of air.(low air-fl ow)
The battery is not charged
enough.
Clogged fi lter.
Clogged fi lter.
The unit works only for a short time.
The battery is not charged
enough .
Fault of charger.
It is impossible to charge the battery..
Bad battery connector .
It is impossible to charge the battery
Termination of battery life time.
suffi ciently.
8.
Storage
All parts of the CleanAIR system must be stored at
temperatures between 0°C and 40°C with relative air
humidity inbetween 20 and 80 % Rh. Maximum storage
life in undamaged wrapping is 2 years
excluding batteries!
During storage self-discharge of batteries occurs.
Batteries stored for long terms must be fully charged
every 6 months.
CA CHEMICAL 2F
2F Plus
Minimum air-fl ow
120 - 235 l/min eligibly in 5 rates
Display
TFT display
Weight of unit including battery
960 g
Unit noise
55 to 61 dB
Battery life time
Max.500 recharging cycles
One recharging cycle
3 - 4 hours
Belt size
75 to 130 cm at waistline
Advised temperature range for work
0°to 40°C
Advised air humidity range for work
20 to 80 % Rh
Certifi cation
EN 12 941/A2 TH2/TH3 ; EN 12 942/A2 TM3
Recommendation
Recharge the battery.
(if the problem outlasts, check the
battery)
Return to the producer for repairing.
Check and remove the possible block.
Check all sealing elements and joints, make
sure the hose is not damaged and without
leakage.
Charge the battery.
(if the problem outlasts, check the battery)
Replace the fi lter.
Replace the fi lter.
Charge the battery.
(if the problem outlasts, check the
battery)
Contact your supplier.
Check the battery contact.
Install a new charged battery.
9.
Warranty
The Quality Warranty ensures you will receive a repla-
cement if a product presents any manufacturing or
material defects within 12 months from the date of
purchase. For batteries it is 6 months from the date of
purchase. The warranty claim must be lodged at sales
organization. At the same time the proof of purchase
must be handed in ( invoice or certifi cate of delivery).
The warranty can be acknowledged only if no inter-
-ventions into the powered respiratory unit and char-
-ger have been made. The warranty does not cover
defects caused by the late replacement of the fi lter or
by using a fi lter which was damaged by cleaning or by
fi lter blow-through.
8
CA CHEMICAL 3F
3F Plus
Minimum air-fl ow
120 a 235 l/min – hood regime, in 5 eligible rates
Display
TFT display
Weight of fi lter unit excluding fi lters
1 420 g
Filter unit noise
55 to 61 dB
Battery life time
500 to 700 recharging cycles
One recharging cycle
3 - 4 hours
Belt size
75 to 130 cm at waistline
Advised temperature range for work
0°to 40°C
Advised air humidity range for work
20 to 80 % Rh
Certifi cation
EN 12 941/A2 TH2,TH3 ; EN 12 942/A2 TM3
Estimated operating time
Air-fl ow
(hours)
(l/min)
160
CA CHEMICAL 2F plus
210
160
CA CHEMICAL 3F plus
210
Notifi ed person for testing CE:
Research institute for labour safety, v.v.i.
Testing laboratory no. 1024
Jeruzalémská 9, 116 52 Praha 1
Accredited person 235
Notifi ed person 1024
11.

List of parts:

CA CHEMICAL 2F
Orde code:
Description:
510000
CA Chemical 2F Plus (unit with battery and indicator)
510000FCA
CA Chemical 2F Plus, set (unit with charger, comfort belt and fl ow indicator)
510010
2F exchangeable battery Li-ION 14,4V/2,6Ah
510043
2F Belt comfort
520044
Comfort harness
510040
Belt decontaminable 50
510041
Decontaminable harness
510045
2F Protection pack
510030EUR
Charger Li-ION 14,4 V EURO
510030UK
Charger Li-ION 14,4 V UK
700060
Light fl exi hose CA40x1/7" - CA40x1/7"
700082CA
Heavy fl exi hose CA40x1/7" - CA40x1/7"
700086Q
Rubber hose CA40x1/7" - CA40x1/7" 25°
700062F
Hose cover fl ameproof
700062C
Hose cover chemical resistant
520090
Flow indicator CA40
CA CHEMICAL 3F
Order code:
Description:
520000
CA Chemical 3F Plus - (unit with battery)
520000FCA
CA Chemical 3F Plus, set (unit with charger,comfort belt and fl ow indicator)
520010
3F Replaceable battery Li-ION 14,4 V/2,6 Ah
520043
3F belt comfort
520044
Comfort harness
520041
Decontaminable harness
510040
Belt decontaminable 50
510030EUR
Charger Li-ION 14,4 V EURO
510030UK
Charger Li-ION 14,4 V UK
700060
Light fl exi hose CA40x1/7" - CA40x1/7"
700082CA
Heavy fl exi hose CA40x1/7" - CA40x1/7"
700086Q
Rubber hose CA40x1/7" - CA40x1/7" 25°
700062F
Hose cover fl ameproof
700062C
Hose cover chemical resistant
520090
Flow indicator CA40
Filter type
Particle
Combined
Combined ABE1
A2 P R SL
P R SL
ABEK2P R SL
10
7
-
7,5
4
-
10
9,5
9,5
8,5
6,5
6,25
9
P R SL
7
4,5
9,5
6,5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Chemical 3fChemical 2f plusChemical 3f plus

Inhaltsverzeichnis