2. Technical data

2.1 General data

2.1.1 Performance and consumption data
ClO
2
preparation capacity
System
at 6 bar
OCD-164
counterpressure
g/h
l/h
-30
30
421
-120
120
426
-220
220
430
-350
350
437
-700
700
933
-1000
1000
948
-1500
1500
970
-2000
2000
996
General concentration range for all systems: 0.5 - 3.3 g/l
1) With max. preparation capacity, shortened reaction time
2) With admission pressure 2 bar higher compared with the pressure at the injection unit
3) Depends on flow losses of solution line up to injection unit
4) Concentration of ClO
solution approx. 3.3 g/l. Inlet pressure for bypass water: 3-8 bar
2
5) Concentration of ClO
solution approx. 2 g/l. Inlet pressure for bypass water: 3-8 bar
2
2.1.2 Temperatures and concentrations
Permissible concentration of NaClO
Permissible concentration of the HCl solution 9.0 % by weight
Permissible ambient temperature
Permissible process water temperature
(bypass water)
Permissible component temperature
(chemicals)
Storage temperature of system
Storage temperature of chemicals
Permissible relative humidity
2.1.4 Connections and weights
Connection for bypass
(water inlet)
164-OCD
DN
-30
-120
-220
-350
20
-700
-1000
-1500
-2000
The solution line must be provided with a pressure
relief valve set to 10 bar.
This is a safety measure for the case that a pressure
Caution
of more than 10 bar occurs in the dilution water line
while the chlorine solution line at the outlet side of
the system is shut.
Max. system
Consumption of
pressure
components
1)
50 Hz
60 Hz
HCl
bar
bar
l/h
10
10
0.7
9
6
2.9
7
7
5.2
9
9
8.3
9
9
16.5
9
9
24
9
9
35
9
6
48
solution 7.5 % by weight
2
5 °C to 40 °C
2 °C to 40 °C
5 °C to 40 °C
-5 °C to 50 °C
5 °C to 40 °C
max. 80 %,
non-condensing
Connection for ClO
2
solution line
Motive water
DN
20
Dilution water requirement for bypass system
2)
Solenoid valve
Bypass pump
NaClO
2
(standard)
internal/external
l/h
l/h
0.7
420
2.9
420
5.2
420
8.3
420
16.5
900
24
900
35
900
48
900
2.1.3 Materials
Components
Supporting frame
Screws, washers and nuts
Reactor
Post-mixer
Piping
Gaskets
Enclosure exhaust device
optional
Motive water
pressure
requirements
bar
l/h
800
800
800
1300
5
1300
1300
1300
1300
In batch mode
3)
4)
Min.
Max.
l/h
l/h
l/h
420
7.7
14
420
31
55
420
56
100
420
89
160
900
179
320
900
258
450
900
383
680
900
517
900
Materials
PP
1.4301
Grey PVC, 1.4571 painted
RAL 6017
Grey PVC
Grey PVC
FPM/PTFE
Weight of system
Connection,
exhaust
device
DN
kg
33
34
34
57
20
62
66
76
82
5)
7

Werbung

Inhaltsverzeichnis
loading