HOW THE AIR CONDITIONER WORKS

Automatic operation
As shown in Figures 1 and 2, Automatic Operation mode selects the operation based on the room temperature data (Ta) when
operation begins.
Heat pump models
Room temperature when operation begins or
when selected again
Room temperature
Setting temperature+1
Setting temperature
Setting temperature–1
The operation mode is selected again after the compressor has remained stopped for 15 minutes.
High POWER operation
When you push the Hi-POWER button during cooling, heating, or A operation, the air conditioner will start the following operation.
(A operation: Auto change over)
• Cooling operation
Performs the cooling operation lower than the setting temperature.
When the room temperature is above the setting temperature. In addition, fan speed is high*.
Once room temperature is within 1°C of the setting temperature.
* Noise level raises in accordance with fan speed.
• Heating operation
Performs the heating operation at 2°C higher than the setting temperature.
ECO timer operation
When you push the ECO button during cooling, heating, or A operation, the air conditioner will start the following operation.
The fan speed will be automatically controlled.
• Cooling operation
In the operation suppression zone, where capacity is kept to the
minimum, overcooling is prevented by raising the temperature setting
by 1°C after 1 hour and by 2°C after 2 hours of operation.
The room temperature is thus regulated between the operation
suppression zone and the set temperature.
• Heating operation
In the operation suppression zone, where capacity is kept to the
minimum, overheating is prevented by lowering the temperature
setting by 1°C after 1 hour and by 2°C after 2 hours of operation.
The room temperature is thus regulated between the set temperature
and the operation suppression zone.
EN
Cooling operation
Fan only operation
Heating operation
Figure 1
Cooling-only models
Room temperature when operation begins or when selected
again
Room temperature
Setting temperature+1
Setting temperature
16
Cooling operation
Fan only operation
Figure 2
Operation
suppression zone
1°C
2°C
1 hour
Set temperature
2 hours
Set temperature
2°C
1°C
1 hour
Operation
2 hours
suppression zone