HOW THE AIR CONDITIONER WORKS

Automatic operation
• The air conditioner selects and operates in one of the operating modes of cooling, heating, or fan only,
depending on the room temperature.
• If the AUTO mode is uncomfortable, you can select the desired conditions manually.
Room temperature in operation
The set temperature +1°C or higher
(in case that the room is hot)
The set temperature –1°C to +1°C
The set temperature –1°C or lower
(in case that the room is cold)
ECO timer operation
When you push the ECO button during cooling, heating or A operation, the air conditioner will start the following
operation.
The fan speed will be automatically controlled.
After setting hours (1, 3, 5 or 9 hours) operation, the air conditioner will stop.

• Cooling operation ( )

In the operation suppression zone, where capacity is
kept to the minimum, overcooling is prevented by raising
the temperature setting by 1°C after 1 hour and by 2°C
after 2 hours of operation. The room temperature is thus
regulated between the operation suppression zone and
the set temperature.

• Heating operation ( )

In the operation suppression zone, where capacity is
kept to the minimum, overheating is prevented by
lowering the temperature setting by 1°C after 1 hour and
by 2°C after 2 hours of operation.
The room temperature is thus regulated between the set
temperature and the operation suppression zone.
Cooling
Performs the cooling operation at a temperature
operation
1°C higher than the setting.
Fan only
Performs the fan only operation (low speed) while
operation
monitoring the room temperature. When the room
temperature changes, the air conditioner will select
the cooling or heating mode.
Heating
Performs the heating operation at a temperature
operation
1°C lower than the setting.
15
Operating condition
1°C
1 hour
2 hours
Set temperature
1°C
1 hour
2 hours
Operation suppression zone
2°C
Set temperature
2°C
Operation
suppression zone