INSTALLATION
M
N
- 70
ADAPTATION FOR PELLET LOADING
SCREW SYSTEM (optional)
The boiler is prepared, on the back (X) and on the right
side (Y), to use an external pellet tank eqipped with a
feeding screw.
ATTENTION: the boiler must be positioned at least 30
cm from the wall behind it
To install the system, proceed as follows:
N.B.:
before starting, turn the boiler off and disconnect the
electricity supply wire.
Fig 1 - 2 -3
• Remove the pre-cut cover on the back (X - fi g. 1) or on
the right side (Y - fi g. 4), and remove the cover screwed
on the pellet tank (Z - fi g. 2), replacing it by the fl ange
connection for the fl exible hose contained in the package
of the external tank (M -fi g. 3).
• The fl exible pellet feeding pipe must be connected to the
fl ange (N) (see system technical diagram).
Fig 4 - 5
• Insert the proximity sensor into the hole on the right side
of the boiler (N - fi g. 4), removing the pre-cut cover fi xed
by two screws.
O
-
N