THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Thermal power transferred to the water
Yield / Effi ciency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Draught
Hopper capacity
Water content
Maximum operating pressure of the
water
Maximum operating temperature of the
water
Pression water capacity
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guide-
lines of this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the
discharge pipe
Minimum draught
Fume fl ow capacity
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and
subsequent changes together with an expected heat output of 33 Kcal/m³ per hour.
ELECTRICAL CHARACTERISTICS
Power supply
On/off switch
Absorbed power in stand-by
Average power consumption
Power consumption during ignition
Protection on mains power supply* (see page 57)
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by quali ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a sine-wave UPS
of at least 800 Va. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certi cation on the part of the noti ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
GENERAL INFORMATION
MAXIMA 14
Nominal power
17,4
16
92
0,016
57
3,6
100
0,12 - 0,05
70
1,5
90
T = 10 K =
27
415
100
40
507
MAXIMA 14
Nominal power
16
69
0 - 0,05
0,013
303-5
according to EN
Reduced power
Nominal power
5,3
25,3
5
24
94,5
94,7
0,038
0,004
52
63
1,1
5,3
P 750
T = 20 K =
88
18
Reduced power
Nominal power
5
24
62
76
0,005
0,014
230Vac +/- 10% 50 Hz
yes
3 W
150 W
400 W
T2A, 250 Vac, 5x20 Fuse
T2A, 250 Vac, 5x20 Fuse
- 56
-
MAXIMA 24
Reduced power
5,3
kW
5
kW
94,5
0,038
52
1,1
kg/h
100
0,12 - 0,05
70
Litres
1,5
bar
90
mbar
P 200
88
hours
625
100
mm
40
mm
533
MAXIMA 24
Reduced power
5
62
0 - 0,05
0,005
%
%
°C
Pa
kg
°C
3
m
kg
kW
°C
mbar
Kg/s