plug connections in an area that is safe
from flooding.
Ensure that the mains voltage matches
the specifications on the rating plate.
The electrical installation shall be ac-
cording to national wiring rules.
Connect the equipment only to a sock-
et with a residual current protection
device (residual current circuit breaker)
with a rated current of not more than
30 mA; minimum fuse 6 amperes.
Before each use, check the equipment,
cable and plug for damage. Defec-
tive cables are not to be repaired, but
rather replaced by new ones. Have
damage on your equipment repaired
by an authorised specialist.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified per-
son in order to prevent hazards.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
Do not carry or fix the equipment by
the cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
Disconnect the mains plug from the
socket before all work on the equip-
ment, in case of leaks in the water sys-
tem, during work breaks, and when not
in use.
The cross-section of mains connection
lines must be no smaller than rub-
ber hose lines with the designation
H07RN-F. The line must be 10 m long.
The flexible lead cross-section of the ex-
tension cord must at least 2.5 mm

Start-up

Assembly

1. Screw the angle adapter (11)
2. Position the float switch cable (7)
Connection of the pressure
line
The installation of the submersible water
pump is implemented either
-
with fixed pipe or
-
with flexible hose line
• If using a ½" hose, attach the
• To use a ¾", 1" or 1½" hose, cut
• To use a tap adaptor (G1") to
Measurement of maximum output
data takes place during direct,
straight pumping. The angle adapt-
er (
per (
.
To increase pump output, the backflow
2
stopper (10) may be taken out of the angle

To screw-on the adapter:

and the adapter with the hose
connection (9) onto the pump
outlet (5).
Installing the float switch
in the float switch grid (8).
hose over the pump's hose con-
nection (9) and fasten it with a
hose clamp if necessary.
off the connection above and at-
tach the hose over the correct con-
nection
(fixing with a hose
connect external hose connec-
tion systems, cut off the two top
connections directly above the
G1" tube thread.
11) and the backflow stop-
10) may reduce output.
GB
clamp).
45