Evaluating The Results - Beurer BM 54 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für BM 54:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
• Press the START/STOP button
pressure monitor. The measurement is then stored in the
selected user memory.
• If the device is not switched off manually, it will switch
off automatically after 30 seconds.
If Bluetooth
®
data transfer has been activated, then after
having confirmed the user memory by pressing the START/
STOP button
, the data is transferred to the "beurer
HealthManager" app (see chapter "7.6 Transferring
measurements").
When connecting for the first time, a randomly genera-
ted six-digit PIN code is displayed on the device, and
at the same time an input field appears on the smart-
phone in which you must enter this six-digit PIN code.
After successfully entering the code, the device will be
connected to your smartphone.
• The Bluetooth
symbol on the display flashes and the
®
blue LED lights up. The blood pressure monitor now at-
tempts to connect to the app for approx. 30 seconds.
• The Bluetooth
symbol stops flashing as soon as a con-
®
nection is established. All measurement data is automa-
tically transferred to the app. Once the data has been
successfully transferred, the device switches off. If the
data transfer was unsuccessful, the blue LED goes out
and "
" appears on the display.
to switch off the blood
29
• If a connection to the app cannot be established after
30 seconds, the Bluetooth
blood pressure monitor switches off automatically after
3 minutes.
Please note that you must add the blood pressure moni-
tor to "My devices" in the "beurer HealthManager" app
to enable data transfer. The "beurer HealthManager"
app must be activated to allow data transfer. If the latest
data is not displayed on your smartphone, repeat the
data transfer as described in chapter 7.6.
If you forget to turn off the blood pressure monitor, it will
switch off automatically after approx. 30 seconds. In this
case too, the value is stored in the selected or most recent
user memory and the data is transferred if Bluetooth
transfer has been activated.
• Wait for at least 1 minute before taking ano-
ther measurement.

7.4 Evaluating the results

Cardiac arrhythmia:
This device can identify potential disruptions of the heart rhythm
when measuring and, if necessary, indicates this after the
measurement with the symbol
This can be an indicator for arrhythmia. Arrhythmia is a condition
in which the heart rhythm is abnormal because of flaws in the
bioelectrical system that regulates the heartbeat. The symptoms
(skipped or premature heart beats, pulse being slow or too fast)
symbol goes out and the
®
data
®
.