Herunterladen Inhalt Inhalt Diese Seite drucken

Checking The Function - GEZE PERLAN AUT-2 Anschlussplan

Inhaltsverzeichnis

Werbung

PERLAN AUT-2
Controller in the state of delivery or after power disconnection:
The red LED flashes twice consecutively with approx. 1.5 seconds break continuously.
Press the Reset button for 2 seconds.
X
The red LED begins to flash continuously:
Checking the direction of movement:
Open with the OPEN button and close with the CLOSE button.
X
If the direction of movement is wrong:
Swap the motor cables, check the direction of movement again.
X
Press the Reset button again for approx. 2 seconds.
X
The red LED lights up permanently, the yellow LED lights up at motor activity.
The sliding door drive moves to the closed position.
The sliding door drive moves to the opened position, first rapidly, then slowly.
The sliding door drive moves to the closed position.
The LEDs extinguish.

Checking the function

Check the desired function.
X
In case of a malfunction check the electrical connections and configuration.
X
If necessary, repeat commissioning.
X
If the function is fault- and error-free, commissioning has been completed.