DATA SHEETS
TECHNICAL SPECIFICATIONS
Short circuit proctection
Reverse polarity protection
Over heat
Storage temperature
Operating ambient temperature
Humidity
Vibration
Cooling
Forced cooling
Environmental protection
Reliability/life time
ELECTRO MAGNETIC COMPATBILITY
Electro Magnetic Emission : better than EN 50081-1
Electro Magnetic Immunity : better than EN 50082-1
Safety
WHAT TO DO IN CASE OF A DEFECT?
Consult factory in Amsterdam, tel. +31-20-3422100, or your local Repair Center
Main PCB of the MASS 24/15-2.
COMPLIANCES
• CE:
Is in conformity with the provision of the EC EMC directive 89/336/EEC and amandments 92/31/EEC, 93/68/EEC.
The following harmonized standards have been applied:
• LLOYDS, DNV, ABS:
MASTERVOLT has constructed this product for rugged circumstances in professional or leisure situations.
This product can be type-approved individually. Price approx. US $ 1500 per certification.
• MANUFACTURED UNDER ISO 9001.
40
: yes, reduced output max. 15 Amps
: yes, by internal fuses
: yes, derating output and shut off by 80°C temperature on heatsink
: -25°C to 80°C
: -20°C to 40°C, derating with 2.5% / °C > 40°C
: maximum 95%, not condensing
: according IEC 68-2-6
: mix of conventional and forced air cooling
: by one variable speed maintenance free DC fan
: IP23
: • MTBF 30.000 hours
• 1/4 life time period, Uin = 207V AC, Uout = 28.5, Iout = 15 Amps at Tamb 40°C
• 3/4 life time period, Uin = 207V Ac, Uout = 26.5, Iout = 15 Amps at Tamb 25°C
(gen. emmission standard, scope; residiential, commercial & light industry)
(gen. emmission standard, scope; residiential, commercial & light industry)
: according to IEC 335-2-29, polarity protected by means of a breaker, short break
10
10
Dimensions of the new cabinet and PCB.
• Generic emission standard
• Generic immunity standard
200
58
48
220
: EN 50081-1:1992
: EN 50082-1:1992
Apendix A
6