7.1.7
Draining the condensate
Read all indicated in Section 6.1 before starting any maintenance jobs.
Drain the condensate from the air tank at least once a month by opening tap 1 secured to the foot
of the tank.
7.1.8
Cleaning the air/oil radiator
Read all indicated in Section 6.1 before starting any maintenance jobs.
It is advisable to clean the radiator 1 on a weekly basis to remove impurities, blowing it with an air
gun from inside.
low compressed air through the radiator, from inside outwards, making sure that no dirt settles
inside the compressor
7.1.9
Electric motor maintenance
The bearings of the electric motor are already lubricated and are maintenance free.
In normal surrounding conditions (ambient temperature up to 30° C) replace the motor bearings
every 12500 hours of use. In more severe surrounding conditions (ambient temperature up to
40° C) replace the motor bearings every 8000 hours of use.
The bearings are to be replaced in any event every 4 years at the most.
Attention!
Before replacing the motor bearings, contact our customer service department, as
established by the maintenance schedule.
The condensate drained is considered as polluting mix that must not be thrown
away outdoors. It is advisable to use special water/oil separators for its disposal.