Interval
Jobs
(hours)
to be performed
Weekly
Check if the filters of the electric cabinet are clogged
Check if the anti-dust pre-filter is clogged
500 hours
Change oil.
after first start
Check the electrical connections and tighten if necessary
Every 2500 h
Replace the oil filter cartridge
or
Replace the filter cartridge of the oil separator
1 year at least
Replace the air filter cartridge
Check the transmission
Clean the air/oil radiator
Check filters in electrical cabinet and replace if necessary
Clean inverter dissipator (if equipped )
Check the safety valve.
Check the electrical connections and tighten if necessary.
Drain condensate....
Change oil
every 7500
Check the hydraulic seals
hours
Overhaul the suction valve
every
Check the hoses and replace if necessary
12500 hours
Overhaul oil separator flange
Grease the minimum pressure valve
Replace Fluorflon pipes 6x4 and 10x10
Replace the screw oil seal
Replace the bearings of the radiator fan motor
Replace the delivery OR flange
Clean the compressor
every 20000 hours
Replace inverter fan (if equipped).
Replace the bearings of the screw (to be done by Technical
Service centre) .
The above described maintenance schedule has been planned bearing in mind all the installation
parameters and recommended use of the Manufacturer.
The Manufacturer advises the customer to keep a record of all maintenance jobs performed on the
compressor, see Section
.
7
– Drawings and diagrams.
85
GB
See
section
7.1.1
7.1.2
7.1.3
7.1.4
7.1.5
7.1.8
7.1.7
7.1.1
7.1.9