6.2J.5

WATER TEMPERATURE SCREEN __________________________________

If the temperature rises to 105°C then both
RED LED's (A) should start to flash at a rate of
two every 4 seconds and a larger temperature
symbol should replace the central icons and
flash. The buzzer will be triggered and the
cutting unit if rotating will stop should the
temperature reach 108°C.The engine will shut
down at 115°C.
This occurrence will also be logged to memory,
the data to be recorded is:
Water Temperature limit reached, Date, Time,
Engine Hours, Time above 100°C
Maximum temperature reached during fault.
6.2J.6

BLOCKED CHARGE FILTER SCREEN _______________________________

This signal will not trigger a fault until the hydraulic
oil is at operating temperature. If the charge filter
becomes blocked the icon will be shown, and the
RED LED's (A) will flash at a rate of a 1s flash
every 5 seconds. The buzzer relay will be
triggered at the same rate of high for 1s every
5 seconds.
The fault will be logged to memory, information to
be stored should be:
Blocked Charge Filter, Date, Time, Engine Hours.,
Length of time engine continued to run after fault
arose.
A
Water Temperature Sensor
-System Fault-
1234.5
A
Blocked Charge Filter Sensor
-System Fault-
1234.5