8
Appendix
8.2
Interface XS2 Reservoir
Only the tanks and product supply devices provided by LOCTITE can be operated at this
interface!
Pin no.:
1
2
3
4
5
6
7
8
9
Pins 5 and 9 are used to supply the tank electronics.
The internal power supply is rated for a maximum of 100 mA. Under no circumstances may a
power supply be connected to these outputs!
56
Function
"Refill" signal input
"Empty" signal input
Internal ground output
Tank valve output
Tank detection input
Internal output +24V
Addition
Not galvanically isolated