Loctite EQ RC15 Bedienungsanleitung Seite 44

Pump controller
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

2
Description
These symbols and the associated adjustment options appear when key 5 Extended Settings is
pressed.
Rotor spray activated – rotor spray not
activated.
Fixed quantity operating mode is selected
(quantity program).
Fixed dosing time operating mode is selected
(time program).
External time control operating mode is
selected.
("Start/stop" or "continuous operation")
Return suck-back volume.
The set quantity of the product is sucked back
after dosing.
Flow rate for the return suction after dosing.
Continue to the screen for the device settings.
Save all parameters and settings.
Accept the set data and return to the main
screen.
The settings can be saved so that they are secured against a power failure or taken over
temporarily. They should only be saved such that they are secured against a power failure if no
changes to the dosing parameters have to be carried out. For experiments or a step-by-step
approach to the dosed quantity, the values should only be adjusted and the screen for extended
settings exited with key 13 ENTER.