2
Description
7
Display of the current program
Up to 3 dosing programs with different dosing parameters can be stored and selected by
their own start signal in each case. The various dosing programs are switched to from the
main screen by touching display field 7. Depending on the program, [X], [Y] or [Z] is then
displayed, as well as the associated parameters. The parameters in the extended settings
menu, such as the return suction volume and return suction speed, are switched over
with the programs as well. Since it is not possible to switch over the programs in the
extended settings menu, this has to be carried out on the main screen. A start signal
enables and displays the current program.
8
Display of the current tank pressure
The tank pressure is displayed and monitored. In the case of significant deviations in the
current value from the stored target value, the device issues an optical and acoustic
alarm. Touching the pressure display field 8 takes over the current pressure as the new
target value and the alarm is canceled.
9
Status symbol for the product supply
Symbol for Reservoir
This symbol shows the current status of the product supply: full, refill, empty, vented or
fault. By touching this symbol, the tank is pressurized and vented.
Symbol for Syringe
This symbol shows the current status of the product supply: full, refill, empty, or vented:
By touching this symbol, the Syringe Reservoir will be activated, as explained in Section
5.7.
: