Description
2.5.4

Screen for the device settings

These symbols and the associated adjustment options appear if the symbol for the device
settings is pressed in the menu for the extended settings.
Reset all user inputs to the factory settings
after a confirmation prompt
Calibrate the pump (move the rotor through
exactly 10 revolutions in order to be able to
measure the dosed volume)
Setting the pump calibration
(dispensed volume per revolution)
Activation of a product tank or product
syringe and setting of the syringe size
(capacity.
Adjustment of the display contrast by
touching one of the two semicircles. The area
between the semicircles should be shown in
gray.
Available from Firmware 0.18 on, and only in
the external time control operating mode.
Adjustment of the ramp up time of the flow
rate. Intended for smooth overlapping of bead start and end. The ramp length may be adjusted
from 0 to 5 seconds. If the ramp up time is set longer than the dispensing time the final flow rate
will not be reached.
Available from Firmware 0.18 on, and only in
the external time control operating mode.
Adjustment of the flow rate ramp down
time, 0 to 5 seconds. This ramp time will always be fully appended to the dispense time, even if
the maximum flow rate should not have been reached due to an excessive ramp up time.