Description
2.5

Displays

2.5.1.

Main Screen

1
2
3
4
5
6
40
Status symbol for the dosage
Dispensing rate in microliters per minute
Dispensing quantity in microliters
Dispensing time in seconds
Key for the menu for the extended settings
The screen is switched so that
– the rotor spray option and the rotor spray lag time,
– the operating mode
– and the parameters for the return suction function can be adjusted.
All parameters can be stored so that they are secured against a power failure and it is
possible to switch to a further submenu for the device settings where
– the contrast of the display can be equalized,
– the pump calibration can be performed and adjusted
– and the device can be returned to the factory settings.
Purge key
Touch the purge key to operate the pump by hand with the parameters of the program
[X] to fill the hose and dosing nozzle or to purge the pump after it has been idle for a
prolonged period. Return suction is not carried out in purge mode, irrespective of the
settings.