DIP switch 6
OFF
DIP switch 7
OFF
Irrespective of automatic activation, the state can be changed by an operating function at all times.
3.4

Interconnected operation (linked operation)

3.4.1
Address setting Doorguard hardwired version
A maximum of 16 Doorguard hardwired version devices can be operated (interconnected) with a 16 DG disable
and display module (Item no. 012542.17) or 16 DG display module (Item no. 012548.17). This disable and display
module enables the display of statuses (e.g. door open, alarm state) and allows activation and deactivation via the
operating keys (only Item no. 012542.17).
Networking is only possible between the individual Doorguard hardwired version devices and a 16 DG
display module or a 16 DG disable and display module!

Switch position

Address setting
DIP switches
S1 to S4
Mounting and Operating Instructions Doorguard hardwired version
Without reminder signal
If the door is opened for longer than 1 minute, an alarm is generated.
Automatic activation
- Automatic activation 1 minute after inactivation when door is closed.
(The door can be opened 1 minute after inactivation). If the door is opened
later, an alarm is emitted
"One-time entry":
- Activation on closing
- Permissible release time without triggering alarm, maximum 1 minute.
- Manual activation is possible.
DIP switches in Doorguard hardwired version
Beginning with address 1 (= 1. Doorguard hardwired version device),
every additional Doorguard hardwired version device must be
allocated its own address. With the DIP switches therefore, 15
addresses can be set for 15 Doorguard hardwired version devices.