A retaining clip should be located on the operating switch.
The retaining clip on the operating switch protects the
switching flag against damage when mounting the half
cylinder.
- Turn the assembly screw (M5 x 16) from the right approx.
10 mm into the selected half cylinder.
- Turn the „lock lug" 90° clockwise into the normal position
(release position).
- Insert the half cylinder into the cylinder mount of the housing
base and screw down. If necessary attach returning spring
to the "lock lug".
- Insert the key in the half cylinder
- Remove the retaining clip on the operating switch
- Test the operating function by turning (key-operated switch) clockwise to the limit.
On releasing the key, the return spring should press the "lock lug" into the normal position. If necessary,
readjust the half cylinder using the assembly screw.
2.3

Close housing

For the combined mounting of both the operating unit and the alarm signalling device, observe the
sequence of mounting the housing covers:
- First insert the housing cover of the operating unit into the housing base (at top) and put it
over the locking cylinder on the housing base.
- Then place the housing cover of the alarm signalling device on the housing base and press
downwards against the operating unit.
- Tighten the housing screws at the top and bottom of the housing.
2.4

Seal housing

Seal the housing after correctly mounting, connecting, programming and testing the system. Ensure that both
housings are correctly closed and screwed tight. Press the enclosed plastic seals into the screw openings at the
top and bottom of the housings to seal. After attaching the plastic seal, the housing can no longer be opened
without destroying the seal.
3.

Programming

The 8 DIP switches located on the operating PCB are used for programming.
The DIP switches must be switched in a de-energized state!
3.1
Operation as individual device (stand-alone operation)
OFF
DIP switches
S1 to S4
DIP switch 8
OFF
Mounting and Operating Instructions Doorguard hardwired version
Switches for operating mode
Stand-alone operation
Stand-alone operation