Mounting and Operating Instructions Doorguard hardwired version
1.

General

1.1

Range of application

The version of the Doorguard hardwired version monitors the opening of emergency exit doors and can be
installed on site. The operating unit and alarm signalling device can be installed separately or in combination so
that installation can be carried out according to the requirements of the premises or application in question. Due
to the integrated power supply unit, the on-site supply voltage required is 230 V AC / 50 Hz.
The door contacts (opening contacts) trigger the alarm at the doors that require monitoring. If an unauthorized
person opens the emergency exit door a local acoustical and optical alarm is triggered immediately.
If the emergency exit door requires opening for an authorized person, monitoring can be deactivated by release.
The green LED "Operating state" at the operating unit of the Doorguard hardwired version indicates the release of
the emergency exit door.
For the remote single indication of several Doorguard hardwired version systems (1 to 16), the 16-DG disable and
display module (Item no. 012542.17 or Item no. 012548.17) can be used as a remote indicating panel
(master/slave operation). It has an optical indicator (2 LEDs) and a key for remote controlled enabling (inactivation
and activation only Item no. 012542.17) for every connected Doorguard hardwired version systems, an acoustical
alarm is also emitted (collective alarm).
1.2

Performance features

! Monitoring of opening of emergency exit doors
! Indication of operating state via green LED
! Indication of "Activation" and "Door open" state via red LED
! Detector group input for opening contact (door contact)
! Detector group input for tamper switch
! Installation possibility of a half cylinder as per DIN 18252
! External operating input for remote operating module (key-operated switch)
! Alarm signalling device for mounting separate from the operating unit (e.g. mounting "above the door")
! Integrated, energy-saving power supply unit for 230 V AC with low power consumption
! Optical alarm signalling device with high-performance LEDs
! Acoustical alarm signalling device with Piezo alarm device
! Resonance-optimized housing for extremely loud radiation of alarm tone on all sides
! Cover and tear-off monitoring of alarm signalling device and operating unit
! Master/slave operation for the networking of max. 16 Doorguard hardwired version systems with:
- a 16 DG disable and display module (Item no. 012542.17) as operating and display panel
- or a 16 DG display module (Item no. 012548.17) only display panel.
25