Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting Heater Sensor F1; Connecting Bench Sensor F2; Connecting The Film Sensor (Optional); Connecting The Safety Shut-Off Device - Sentiotec just sauna fin Montage- Und Gebrauchsanweisung

Saunasteuerung
Vorschau ausblenden Andere Handbücher für just sauna fin:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation instructions, only for experts

5.7. Connecting heater sensor F1

1. Guide the wires for the heater sensor through the cable bushing
low-voltage connection area
2. Connect the red wires for the heater sensor to the terminals labelled "STB"
in terminal strip
3. Connect the white wires for the heater sensor to the terminals labelled "F1"
in terminal strip

5.8. Connecting bench sensor F2

1. Guide the wires for the bench sensor through the cable bushing
low-voltage connection area
2. Connect the wires for the bench sensor to the terminals labelled "F2" in
terminal strip
5.9. Connecting the fi lm sensor (optional)
1. Guide the wires for the sensor through the cable bushing
voltage connection area
2. Connect the wires for the sensor to the terminals labelled "FF" in terminal
strip
.
2

5.10. Connecting the safety shut-off device

EN 60335-2-53 states that sauna control units with a remote start or preset timer
function may only be used for operating and regulating a sauna heater which
has satisfi ed the combustion test described in paragraph 19.101. Alternatively,
a suitable safety shut-off device can be installed in or above the heater. This shuts
When the remote start function is deactivated, you may also use the sauna
control unit just sauna with a safety shut-off device. In this case, bridge
terminal "OSG" in the low-voltage connection area
WORLD OF WELLNESS
1
.
2
.
2
1
.
2
.
1
.
.
p. 21/44
into the
6
into the
5
into the low-
5
using a wire jumper.
1
EN

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Just-105d-fiJust-105w-fi

Inhaltsverzeichnis