Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch FWA 4630 Erstinbetriebnahme Seite 12

Achsmessgerät
Vorschau ausblenden Andere Handbücher für FWA 4630:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
12 | FWA 4360 | Commissioning of sensors
4.
Commissioning of
sensors
4.1
Fitting /position of adapters
Depending on the design of the measurement bay (e.g.
pit, scissors-type lifting platform, 4-column lifting plat-
form) attach an appropriate adapter at the sensor and
measurement bay. Fitting is described in the separate
instructions included with each adapter.
i
The two reference cameras must be in visual con-
tact. Make sure the height of the sensors is selected
accordingly.
i
With floor-level and under-floor platforms make sure
the sensor is not in contact with the floor with the
platform lowered. Ensure a clearance from the floor
of at least 10 mm.
i
For lifting platforms with adjustable runways, make
sure the correct spacing value has always been
stored in the program.
Fig. 3:
Distance between turntable and sensor
1.
Determine the sensor position with the shortest
distance from the turntable (Fig. 3).
Attach the adapter to the left side of the measure-
2.
ment bay. The distance between the center of the
turntable and the center of the sensor should be
930-950 mm.
|
|
1 690 706 006
2009-05-19
3.
Attach the adapter to the right side of the measure-
ment bay in the same way as for the left side.
Terminate the wheel alignment program.
4.
5.
use the right mouse key to start <Easy 3D service
functions> in the task bar.
6.
Select <Display
> with the right mouse key.
7.
Continue with <System
?
The
CCD reference system is initialized.
?
The measured values of the CCD reference system
are displayed.
Fig. 4:
Sensor alignment
8.
If the values for the left and right toe, the left and
right camber and the left and right level differ by
> +/-1°, align the sensors using the platform adapter
adjusting screws.
9.
If the values are OK, close the window with "ESC".
10.
Start the wheel alignment program.
11.
In the <Service
> <Settings> menu, enter distance
values in "mm" or "inches" in the dialog window
and confirm with OK.
"
The sensors are ready for operation.
Fig. 5:
Measurement points for determining sensor spacing
><CCD reference system>
Robert Bosch GmbH

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis