7. Adjustments
7.3
Third display field: COcal (Calibrating value for CO-indicator)
COcal:
+1
+10
K
The COcal calibrating value will be set as described above (cfr. 7.1). This adjustment
menu should be used only for readjusting the CO indicator.
Higher offset value
Lower offset value
As soon as the Setup menu is being quitted by double-clicking "OK" or "Cancel", the
device will continue the CO measuring. The calibration values set will be preserved by
the device also in no power supply condition.
Manual Instruction
478
-1
-10
OK
STOP
= increase of CO display
= lower display
40
q
Fig. 17