Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Elements - Wohler Econometer E 98 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. Operating elements

2.
Operating elements
1 Display
2 Charging terminal
3 On/Off and control key
4 Connection for combustion air temperature sensor (on bottom face)
5 Pressure connection for burner adjusting operations
6 Battery case (at the side of the device)
7 Infra-red interface (at the side of the device, above the battery case)
8 Water stop filter
9 Cotton wool filter
10 Heat exchanger
7
6
1
4
The dry batteries are part of the delivery and may be replaced by 4 NiCD accus or by 4
NiMH accus. Mains supply will not be possible!
Normal charging equipment: The plug of the charger will be plugged into the
charging terminal. Charging time will be approx. 15 hours. The accus should be empty to
begin with (memory effect). After the accus are charged, the charger will switch off.
Quick charging equipment: The plug of the charger will be plugged into the charging
terminal (Charging time for NiCd: approx. 50 minutes; for NiMH: approx. 1 h). The
charging control will discontinue the charging procedure automatically as soon as the
accus are charged. The quick charging equipment will recognize the voltage condition
of the accus.
Manual Instruction
10
8
9
26
q
3
5
2

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis