ABIPLAS
WELD CT
1
1
Coolant return hose
2
Coolant supply hose
Fig. 8
Connecting the coolant
BAL.0128 • 2018-02-05
NOTICE
• Ensure that the coolant supply and return hoses have been correctly
installed. Coolant supply = blue, coolant return = red
• Do not use deionised or demineralised water as coolant or for leak and
flow tests.
This may shorten your welding torch's service life.
• For liquid-cooled welding torches, we recommend using
ABICOR BINZEL BTC coolant.
Please consult the applicable safety data sheet.
Bleed the entire cooling system as follows when used for the first time and after
every cable assembly replacement:
1 Disconnect the coolant return hose (1) from the coolant recirculator (3) and
hold it over a collection receptacle.
2 Seal the opening on the coolant return hose (1) then re-open it by abruptly
releasing it. Repeat this process until the coolant flows into the collection
receptacle continuously and without air bubbles.
3 Switch off the coolant recirculator (3) and reconnect the coolant return
hose (1).
2
3
Coolant recirculator
4
Control lead
6 Putting into operation
3
4
EN - 17