WELD CT
1
1
Coolant return hose
2
Coolant supply hose
Fig. 8
Connecting the coolant
BAL.0128 • 2018-02-05
NOTICE
• Ensure that the coolant supply and return hoses have been correctly
installed. Coolant supply = blue, coolant return = red
• Do not use deionised or demineralised water as coolant or for leak and
flow tests.
This may shorten your welding torch's service life.
• For liquid-cooled welding torches, we recommend using
ABICOR BINZEL BTC coolant.
 Please consult the applicable safety data sheet.
Bleed the entire cooling system as follows when used for the first time and after
every cable assembly replacement:
1 Disconnect the coolant return hose (1) from the coolant recirculator (3) and
hold it over a collection receptacle.
2 Seal the opening on the coolant return hose (1) then re-open it by abruptly
releasing it. Repeat this process until the coolant flows into the collection
receptacle continuously and without air bubbles.
3 Switch off the coolant recirculator (3) and reconnect the coolant return
hose (1).
2
3
Coolant recirculator
4
Control lead
6 Putting into operation