6.5 Connecting the cable assembly
6.6 Attaching the connector to the device
BAL.0128 • 2018-02-05
8 Screw the knurled screw (11) for the cold-wire feeder (12) into the
bracket (16).
9 Unscrew the knurled screw (11) enough to allow the cold-wire feeder (12)
to be pivoted out laterally.
10Screw the feeding nozzle (13) onto the cold-wire feeder.
11 Position the cold-wire feeder (12) and tighten the knurled screw (11).
CAUTION
Mechanical hazard
A loose torch body can result in a mechanical hazard.
• Check that the torch body and cable assembly are firmly attached.
1 Join the welding cable plug and socket at the power source and lock them.
2 Connect the emergency stop cable, pilot power source and power source.