Differenzregler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Para-
Function
meter
F1.11 DIFFERENTIAL THER-
MOSTAT
F1.12 HEAT SOURCE SEN-
SOR FOR DIFF. THER-
MOSTAT
F1.13 HEAT SINK SENSOR
FOR DIFF. THERMOS-
TAT
F1.14 SWITCH- ON DIFFE-
RENCE FOR DIFFEREN-
TIAL THERMOSTAT
F1.15 SWITCH- OFF DIFFE-
RENCE FOR DIFFEREN-
TIAL THERMOSTAT
F1.16 CIRCULATION ON
OUTPUT
F1.17 SWITCH-ON IMPULSE /
CIRCULATION PUMP
RUNNING TIME
F1.18 SWITCH-ON DELAY /
CIRCULATION PUMP
STANDBY TIME
Parameter description
Selection if programmed output should operate as a
differential thermostat.
Selection of heat source sensor (higher temperature) for
differential thermostat.
Selection of heat sink sensor (lower temperature) for
differential thermostat.
Switch -on difference setting for differential thermostat.
Switch -off difference setting for differential thermostat.
Selection if output should be used for hot water circulati-
on and the way it should operate.
1- circulation with pump running and standby time
2- circulation is activated with flow switch on terminal T3
and is running for setted running time
3- circulation is activated with flow switch on terminal T4
and is running for setted running time
4- circulation is activated with flow switch on terminal T5
and is running for setted running time
5- circulation is activated with flow switch on terminal T6
and is running for setted running time
This function activates output for setted time. After setted
time expires, the output is switched off, regardless to
other switch-on or switch-off commands.
This setting is especially useful for control of support
pump in Drain-back systems.
Setting 0 means there is no delay and the output should
activate immedately and stay activated for the whole time
of switch-on command.
This function delays activation of output for setted time.
Output is activated when setted delay time expires.
REMARK: If delay time is longer as time of switch-on
period the output won't activate.
Setting 0 means there is no delay and the output should
activate immedately and stay activated for the whole time
of switch-on command.
39
Default
Setting range
value
0- NO
1- YES
2- YES, INVERTED
1- T1 2- T2
3- T3 4- T4
5- T5 6- T6
1- T1 2- T2
3- T3 4- T4
5- T5 6- T6
4 ÷ 30 °C
1 ÷ 20 °C
0- NO
1- YES, RUN/STANDBY
TIME
2- YES, T3
3- YES, T4
4- YES, T5
5- YES, T6
0 ÷ 3600 s
0 ÷ 3600 s
Service settings manual
0
3
4
8
3
0
0
0