Herunterladen Inhalt Inhalt Diese Seite drucken

OEG KSW-E series Bedienungsanleitungen Seite 36

Differenzregler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Table with description of parameters
Para-
Function
meter
OUTPUT PROGRAM-
F1.1
MING
F1.2
DEPENDENCE TO
OTHER OUTPUTS
F1.3
DEPENDENT OUTPUT Selection of output on which depends operation of pro-
TIME PROGRAM FOR
F1.4
OUTPUT
F1.5
THERMOSTATIC
OPERATION OF
OUTPUT
F1.6
TYPE OF AUXILIARY
HEAT SOURCE
F1.7
SENSOR FOR THER-
MOSTATIC OPERATI-
ON
F1.8
THERMOSTAT
HYSTERESIS
F1.9
AUXILIARY HEAT
SOURCE - DELAYED
ACTIVATION
F1.10 AUXILIARY HEAT
SOURCE - STANDBY
AT MIN. TEMPERATU-
RE
Service settings manual
Parameter description
Selection of output for programming.
Define dependence of programmed output to other control-
ler's outputs.
&- selected relay has to be switched-on for programmed
output to be able to switch- on
&!- selected relay has to be switched-off for programmed
output to be able to switch- on
I- programmed output will switch-on always when selected
relay is switched-on
I!- programmed output will always switch- on when the
selected relay is switched-off
grammed output.
Selection of required time program for programmed output. 0- NO
Selection if programmed output operates as a thermostat.
Selection of type of heating source.
Selection of sensor for thermostatic operation.
Hysteresis for thermostatic operation.
Selection if auxiliary heat source should activate
immediately or with delay if the collectors have trend and
tendency to warm the water to requested temperature.
Delay time is considered as a time in which the collectors
should warm the water to requested temperature. Auxiliary
heat source will activate immediately if collectors don't
have trend and tendency to warm the water to requested
temperature in setted delayed activation time.
Selection if auxiliary heat source should permanently heat
the water to min. temperature.
:
38
Default
Setting range
value
0- NO
1- R1
2- R2
3- R3
0- NO
1- &
2- &!
3- I
4- I!
1- R1
2- R2
3- R3
1- P1
2- P2
3- P3
4- P4
5- SEL. PROG. TIMER
0- NO
1- YES
2- YES, INVERTED
3- YES, AUX. SOURCE
4- YES, CASC. SOURCE
1- BURNER
2- EL. HEATER
3- HEAT PUMP
1- T1 2- T2
3- T3 4- T4
5- T5 6- T6
1 ÷ 30 °C
0- NO DELAY
1 ÷ 1440 min- DELAY
0- NO
1- YES, BY TIME PR.
2- ALWAYS
0
0
2
0
0
0
4
4
0
0

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ksw seriesKs2w series

Inhaltsverzeichnis