Asset Management Function - VEGA VEGAPULS WL S 61 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für VEGAPULS WL S 61:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PC with PACTware/DTM
Control system with EDD
8.3

Asset Management function

The instrument features self-monitoring and
diagnostics according to NE 107 and VDI/
VDE 2650. In addition to the status messages
in the following tables there are more detailed
error messages available under the menu item
"Diagnostics" via app or PACTware/DTM.
Status messages
The status messages are divided into the
following categories:
Failure
Function check
Out of specification
Maintenance requirement
and explained by pictographs:
1
2
Abb. 31: Pictographs of the status messages
1
Failure - red
2
Out of specification - yellow
3
Function check - orange
4
Maintenance - blue
Failure: Due to a malfunction in the instrument,
a fault message is output.
Function check: The instrument is being
worked on, the measured value is temporarily
invalid (for example during simulation).
Out of specification: The measured value is
unreliable because an instrument specification
was exceeded (e.g. electronics temperature).
Maintenance: Due to external influences, the
instrument function is limited. The measurement
is affected, but the measured value is still valid.
Plan in maintenance for the instrument because
a failure is expected in the near future (e.g. due
to buildup).
Information:
The status messages are always active.
It cannot be deactivated by the user.
VEGAPULS WL S 61 • 4 ... 20 mA
3
4
8 Diagnosis, asset management and service
Failure
Code
Cause
Text mes-
sage
F013
Sensor does not
detect an echo
no measured
during operation
value availa-
Antenna system
ble
dirty or defective
F017
Adjustment not
within specifi-
Adjustment
cation
span too
small
F025
Index markers
are not conti-
Error in the li-
nuously rising,
nearization
for example
table
illogical value
pairs
F040
Hardware defect
Error in the
electronics
F080
General soft-
ware error
F105
The instrument
is still in the
Determine
start phase, the
measured
measured value
value
could not yet be
determined
F113
EMC interfe-
rence
Communica-
tion error
F125
Temperature of
the electronics
Impermissib-
in the non-
le electronics
specified range
temperature
Rectification
Check or correct
installation and/
or parameter
settings
Clean or
exchange pro-
cess component
or antenna
Change adjust-
ment according
to the limit
values (diffe-
rence between
min. and max.
≥ 10 mm)
Check linearisa-
tion table
Delete table/
Create new
Exchanging the
electronics
Send instrument
for repair
Disconnect ope-
rating voltage
briefly
Wait for the end
of the switch-on
phase
Duration up to
approx. 3 minu-
tes depending
on the version
and parameter
settings
Remove EMC
influences
Check ambient
temperature
33