Electric Crimping Machine AT-300
Key position III:
Off. The machine is inoperable, however
there is still voltage. Any operation is
impossible.
The display (Fig. 4.10) shows the following
icon:
4.4.3

Release Button

In case of jammed jaws caused by operation
or
handling
terminals the electrical crimping machine
AT-300 can be opened as follows:
+
Press the release button (Fig. 4.11) The
tool opens the jaws.
+
Remove the damaged contact and dispose it.
After having pressed the released button, the
following icon appears:
errors
or
wrongly
placed
(Fig. 4.12).
Seite / Page 56 / 85
IS412-94328 Rev. B
Fig. 4.9
Counter:
759.103
Fig. 4.10
Fig. 4.11
Counter:
759.103
Fig. 4.12