Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting; Fcb400, Fch400 In Integral Mount Design With Dual-Compartment Housing - ABB CoriolisMaster FCB100 Anweisung

Vorschau ausblenden Andere Handbücher für CoriolisMaster FCB100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

CORIOLISMASTER FCX100, FCX400 SEALING OF DEVICES | IN/FCX100/FCX400/MID/OIML-XA REV. A
3

Mounting

3.1
FCB400, FCH400 in integral mount design with
dual-compartment housing.
NOTICE
Before the device is sealed, any settings must be
completed and the write protection switch must be set to
"write protection active" (see chapter 'Activating the
hardware write protection' on page 3 ).
Scope of delivery
1
2
3
Fig. 3
Item
Designation
1
Holding rod
2
Locking cylinder
3
Head hole screws
Seal
Seal wire
Preparation
Fig. 4
1.
Loosen two of the four screws
replace with head hole screws
2.
Unscrew both fixing screws
cover of the dual-compartment housing and replace
with the holding rods
G12350
Quantity
2
2
2
1
2
on the foot and
.
1
5
on the front and rear
2
.
EN – 5