8.4

Replacing sleeve-cutting blades

CAUTION
Risk of injury posed by sharp
blades!
Use forceps to change the
blades.
Dispose of the removed blades
in a separate container.
Switch the machine off.
Open the front flap (Figure 3.1, 3).
Press the transport bolt upwards (3).
Remove the wire-end ferrule belt.
Release the screw (1) with a size 4 Allen
key.
Remove the transport unit (2) in an upwards
direction.
1
3
Figure 8.3 Transport unit
46
Use a 2.5 size Allen key to remove both
screws (4).
Remove the isolating blade cover (5).
Note the installation position of the
sleeve-cutting blade.
Replace the sleeve-cutting blade (6) with a
new one.
Installation in reverse order.
Make sure the top edge lies flush when
installing the transport unit.
4
5
Figure 8.4 Replacing sleeve-cutting blades
2
Figure 8.5 Transport unit top edge
6