Please heed the safety instructions in chapter 1.
All power should be disconnected from the system when any main-
tenance or service work is being performed. If the two 9-volt batte-
ries in the control unit are to be replaced, use only 450 mAh types.
Repairs to this system should only be handed by the manufacturer.
The control unit itself requires no maintenance.
Cable connections should be checked for damage.
The SonicControl sensor needs to be cleaned on a regular basis.
Proper operation of the back up / flooding sensor (if included) must
be checked during the semi-annual inspection and maintenance of
the system! This can be done by simply placing the back up / flood
sensor under water (approx 10 cm) which after max 4 seconds
should result in the control unit displaying an optical and audible
alarm.
Every time the oil / coalescence separator is emptied / disposed,
the sensor must be cleaned with warm/hot water*. When a high-
pressure jet cleaner is used, maintain a safe distance of 30 cm.
The sensor does not have to be removed for cleaning.
The SonicControl control unit and the sensor are connected
by a cable with a maximum total length of 30 meters. Only
this cable should be used, no other cable is allowed for connection.
The control unit will only display a grease thickness layer 24 hours after being placed into operation due to the fact that the
reading is taken at night, "-" will be displayed until then.

6. Inspection and Maintenance

53
Beware of all operations on the vessel or to the sensor housing.
Risk of electrostatic charging due to friction and flow of fluids! Elec-
trostatics is a potential source of ignition of flammable materials or
gases. Sensor housing and cables Clean with damp cloth.
The sensor may not be used with corrosive fluids.
The sensor is maintenance free. In order to assure proper operation
of the entire system, the sensor function should be checked once
per year.
Repairs
The SonicControl system may not be repaired, changed or mani-
pulated. In case the SonicControl is damaged or defective it must
be replaced by a new system.
Disposal
In the case that the SonicControl is damaged or no longer required
and needs to be disposed of, please follow all local and national
disposal regulations in your area.
The SonicControl control unit contains two 9-volt batteries which
should be disposed of properly.
Please follow this all the safety instructions in this operating manual
when operating this system.