Please heed the safety instructions in chapter 1.
The switch unit must be completely disconnected from the mains
for cleaning. When replacing the batteries, use Mignon AA 1200
mAh. Repairs may only be carried out by the manufacturer.
The switch unit does not require any maintenance.
The connection cables must be checked for damage. If any da-
mage can be detected, the system must be put out of operation
immediately.
The sensor has to be cleaned at regular intervals.
The control unit will only display a grease thickness layer 24 hours after being placed into operation due to the fact that the reading
is taken at night.

6. Inspection and Maintenance

Every time disposal takes place the sensor must be cleaned with
warm/hot water*. When a high-pressure jet cleaner is used, main-
tain a safe distance of 30 cm.
The sensor does not have to be removed for cleaning.
* In the case of KESSEL M and PV grease separator systems, clea-
ning can wait until the next servicing date since the separator is
automatically cleaned with warm water. If necessary (heavy sen-
sor soiling) carry out cleaning every time disposal is carried out.