Installation SonicControl
The SonicControl should be completely dis-
connected form power before the system is
installed or during any maintenance work.
The system should only be connected to
power after the control unit and the ultraso-
nic sensor have connected. The ID sticker
on the control unit should not be removed.
3.2 Installation of sensor and sensor
bracket
The sensor may be installed in the potenti-
ally explosive area zone 0 until 19.4.2016 in
compliance with guideline 94/9/EC and from
20.4.2016 in compliance with guideline
2014/34/EU.
The cable and the ID sticker are an integral
part of the product. The ID sticker must re-
main on the cable if the cable is to be shor-
tened. If a conduit is required to lay the
3. Installation and Assembly
cable, it is recommended that a conduit with
50mm diameter is used.
The ultrasonic sensor is IP 68 protected and
is weather and oil / fuel resistant – due to
this is can be installed in oil and coalescence
separators.
The ultrasonic sensor is designed for use in
temperatures from -10 deg C to + 50 deg C
(263K to 323K)
Sensors certified for use in explosion
risk areas
In oil and coalescence separators, sensors
can only be installed that are certified for
use in explosion risk areas.
The ultrasonic installation bracket must be
installed with the supplied screws inside the
upper section of the fuel separator – this
area is above fluid level meaning the instal-
lation screws holes will not cause any leaks
to the watertight system.
Caution!!!! If the ultrasonic sensor is being
installed in a fuel or coalescence
separator that is already in use, no
electric or battery powers tools
such as drills may be used during installati-
on. Only use normal hand help screw dri-
vers.
If back-up (flooding) has occurred within the
separator, the ultrasonic sensor should be
inspected afterwards that it is still in the pro-
per location and then it is clear of debris.
Attach the enclosed sticker (registration,
product) in the vicinity of the switching de-
vice on the sensor cable
Please note the safety instructions!