3.3 Installation of sensor holding bracket.
1. Open the cover on the oil or coalescence sepa-
rator (use caution removing the heavy cast iron
or concrete covers – a lifting aid system is re-
commended.
2. Using the including drilling template bracket,
mark on the upper section of the separator the
two holes located on the bracket. Drill two 6mm
holes in the location of the two marks.
3. Screw two included screws into the two holes in
the upper section until there is a distance of
25mm between screw head and upper section
wall.
4. In the case that the separator has installed dee-
per than the standard installation depths, use
the supplied pipe (D) as an extension.
5. Now clip the SonicControl sensor in the holding
clips (C) and then secure the bracket (B) by
hanging it onto the two screws. Now fully tighten
the two screws so that the bracket is securely
fixed to the separator's upper section
6. Now adjust the SonicControl sensor to the
green mark on the sensor with the full water
level (for information on the sensor green mark,
please see the next page.
3. Installation and Assembly
B
C
Caution:
The SonicControl's cable should not be in the way or above any of
the sensor probes (in the water).
45
D
A
Caution
do not drill
through sea-
ling gasket!