1 - INSTRUCTIONS FOR INSTALLATION

1.1 Identifying the models
Serie 700 Serie 900 Serie 110
Enbloc cooker
8031
with 1 basin of 26
39221
litres
Enbloc cooker
with 1 basin of 40
litres
Enbloc cooker
8031
with 2 basins of
39541
26 litres
Enbloc cooker
with 2 basins of
40 litres
1.2 Technical data
The technical data of these apparatuses are indicated in the
attached TableT1.

2 - GENERAL INSTRUCTIONS

Read the instructions of this handbook carefully because they
supply important information on installation, use and
maintenance safety. Keep this handbook carefully for any further
reference
of
the
various
transformation and maintenance of this equipment must
exclusively be carried out by qualified installers or by proper
companies complying with the safety rules in force.
The Manufacturer declines any liability if these rules are not
complied with.
2.1 Installation
- After unpacking, check that the equipment is intact. In case of
any doubt, do not operate this apparatus and call immediately
a professional engineer.
- Arrange the packing elements far from children, because they
can be dangerous.
- The equipment must definitively be installed in the position it
occupies in the kitchen, preferably under an exhausting hood
for a proper recirculation of air.
- The equipment must be installed only in rooms with a good
ventilation.
- The installation of any equipment of the type B11 must be
carried out in such a way that exhaust gases are sent to a
proper system constructed according to the standards in force.
The connection stack is supplied separately.
- Specify the type of installation crossing the proper square: A1 -
B11 - B21, of the rating plate (included in the control board).
- These cookers can be installed separately, or assembled with
other equipment of our line.
- This equipment is not available in built-in version.
- The equipment must be positioned at least 10 cm far from any
wall surrounding it.
- In case of fire-proofing, or thermally insulated walls, this
distance can also be reduced.
- The overall dimensions of the equipment are indicated in the
following pages.
2.2 Installing the connection stack (Fig. 6)
Apply the stack to the cooker. Fasten the stack to the equipment
with the three screws V (fig. 6), supplied with the stack.
8032
49221
8031
49221
8032
49541
8031
49541
operators.
The
installation,
2.3 Installation under exhausting hood (Fig. 7)
When installing the equipment under an exhausting hood, apply
the connection stack (without draft switch), as it is explained in
the previous point 2.2; then lift it at a height of at least 180 cm
from the ground. The distance between the stack end and the
filter of the hood must be included between 125 and 200 mm
(Fig. 7).
2.4 Installing the draft switch (Fig. 8)
When required by the rules in force, the draft switch (supplied
separately) must be applied as follows:
- install the stack following the instruction of the point 2.2
- apply the draft switch to the stack
- insert the exhaust pipe (diameter of 150 cm), for the
connection to the outside, in the sleeve of the draft switch.
2.5 Assembling
- Remove the protection film from the outer surfaces of the
apparatus. Clean these surfaces from probable residual
adhesive using a proper solvent.
- Level the apparatus turning the proper adjustable feet.
- In stand-alone version, the cooker has a width of 40 cm and it
must be fixed to the floor with the proper flanges (Fig. 3).
- As regards the assembling of the connection stack (when
necessary), refer to the point 2.2.
- As regards the assembling of the draft switch (when
necessary), refer to the point 2.4.
2.6 Aligning the equipment (Fig. 2)
Operate as follows:
- Remove the knobs and the control board of the top.
- Arrange the apparatuses side by side and level at the same
height.
- Fasten the apparatuses with the proper screws, as shown in
the fig. 2.
2.7 Connection to the gas pipe network
- Before connecting the equipment, consult the gas service
company.
- Insert a cutoff cock before the apparatus, in an easily
accessible position.
- Make sure that there are no leaks in pipe unions.
- Check whether the equipment is prearranged for the feeding
gas; if necessary, adapt the apparatus to the type of gas
supplied by the gas service, after reading the paragraph 3
carefully.
- In Denmark, before connecting the equipment to the gas pipe
network, screw the nipple supplied with the apparatus, on the
feeding ramp.
2.8 Connection to the water system
- Connect the water inlet pipe to the water system inserting a
mechanic filter.
- Furthermore, insert a cutoff cock before the apparatus, in an
easily accessible position. Before connecting the filter, make
the water run for some time to allow the elimination of possible
ferrous scales from the pipes.
2.9 Draining the water (fig.9)
- The draining pipe must be connected to a continuous system;
furthermore, insert a funnel for a free discharge.
- The pipes must be of heat-resistant material.