4. Programming the control. When the chair leaves the factory, the parameters of the controller are set to default.
Note: SUNRISE MEDICAL does not accept responsibility for damages which result from unexpected stopping of the
wheelchair or inappropriate programming or unauthorised use of the wheelchair.
Note: Programming the controller of the wheelchair is only allowed through authorised Sunrise Medical agents.
Wrong controller settings could cause driving outside the safe limits and could cause damage and injury.
F. CONTROLS AND MAINTENANCE
Charge battery
Check battery level indicator
Ensure all removable parts are securely fastened
Check all the electrical connections
Wipe vehicle with a damp cloth
Check tyre pressures
Chek tyres for wear
Clean and protect the battery terminals with petrolleum jelly
Check condition of upholstery
Complete inspection and service by an authorised supplier
G. SPECIFICATIONS
Effective seat width
Effective seat depth
Backrest height
Overall length (w/legrest)
Overal width
Climbing ability upwards
Seat surface height at front edge
Footrest to seat distance
Armrest to seat distance
Folded length
Folded width
Folded height
Total mass (w/batteries)
H. GUARANTEE
SUNRISE MEDICAL guarantees this product for two years as from the date indicated on the invoice, receipt or
delivery note. For products containing batteries, the battery warranty is 6 months. This warranty covers parts in
need of replacement, labour and transport.
In warranty claims the user must submit the product and the purchase invoice as proof of delivery date.
This warranty does not cover:
NORMAL WEAR AND TEAR, e.g. on upholstery, tyres, inner tubes, rims, wheels, fabric, etc.
ACCIDENTS, e.g. bent structures, scratches, flat tyres, etc.
IMPROPER USE and damage caused by users who weigh more than the weight limit indicated in the user's
manual.
LACK OF MAINTENANCE and failure to follow the conservation instructions in the user's manual.
MODIFICATIONS or REPAIRS carried out by persons not authorised by Sunrise Medical.
PRODUCTS WITH NO INVOICE OR SERIAL NUMBER (when appropriate).
Min.
Max.
430 mm.
Seat plane angle
420 mm.
Backrest angle
470 mm. 495 mm. Leg to seat surface angle
1060 mm.
Max. Speed forward
600 mm. 635 mm. Obstacle climbing (w/kerb climb.)
10°
Max. safe slope
510 mm.
Min. Turning radius
420 mm. 490 mm. Max. User weight
180 mm
300 mm
Mass of the heaviest part
770 mm
(frame without detachable parts
350 mm.
and batteries)
940 mm.
63 kg.
Daily Weekly
Monthly
X
X
X
X
X
X
X
Quarterly Annually
X
X
X
Min.
Max.
70º
6 km/h.
50 mm.
100 mm.
10°
900 mm.
120 kg
29 kg.
20