Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages - Husqvarna RC 455 Bedienungsanweisung

Wandsägen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Menu functions
5.5 PIN code
When the function is actuated a four digit PIN code is
requested each time the remote control is switched on.
The first time the code is 0000. When the wrong PIN code
is stated 4 times in succession the hydraulic unit is locked.
A PUK code (provided by Husqvarna) must then be stated
to unlock the unit.
The display shows: PIN code and ON or OFF.
To activate or deactivate:
Press OK to switch between ON and OFF.
Press the down arrow to continue to the next part
menu.
5.6 Change the PIN code
Press OK when the display shows CHANGE PIN
CODE.
State the current PIN code and press OK
When changing for the first time the code is 0000.)
State the new PIN code and press OK.
State the new PIN code again to confirm and press
OK.
Press the down arrow to go to "Back to the menu".
6. Basic setting
This function restores all the menu settings to the factory
settings. The PIN code is also restored.
The display shows: DEFAULT SETTING and ON or OFF.
OFF is shown when a change has been made that differs
from the default settings.
7 Out settings
This function confirms or rejects all settings made before
the operations menu is shown again.
Press OK when the display shows OUT SETTINGS.
The display shows: SAVE? NO. To not implement the
made settings:
Press OK.
To implement the made settings:
Press arrow up/down to select YES.
Press OK.
22 - English

Error messages

Ten different error messages can be shown on the display:
NOTE! LOW VOLTAGE (1A) CHECK THE VOLTAGE
SUPPLY AND THE CABLE TO THE HYDRAULIC
UNIT
LOW VOLTAGE PHASE X (1B) LOW POWER 32A
MOTOR PROTECTION TRIPPED (2)
MOTOR OVERHEATED (3) COOLING IN
PROGRESS. DO NOT SWITCH OFF THE ELECTRIC
MOTOR
OIL TEMP. HIGH (4) CHECK THE WATER TO THE
HYDRAULIC UNIT
PRESSURE SENSOR OUT OF (5) ORDER
HIGH HYDR PRESSURE (6) CHECK UNIT
NO CONTACT CHECK THE CAN CABLE (7)
NO RADIO CONTACT (8)
Error message (1A)
NOTE!
Low voltage Check the voltage supply and the
cable to the hydraulic unit
Too low voltage, caused by:
Long mains cable.
Too small core size (cross-section) on the mains cable.
One or more phases down, caused by:
A fuse has blown in the distribution box.
Cable breakage.
No voltage to one or more phases in the distribution
box.
Action (1A)
Press OK to acknowledge the error message. The hydraulic
unit will match the maximum power output to 32 A.