9. Press OK to execute calibration
To calibrate the maximum point:
NOTE!
Calibrate the zero point (see previous page)
before the maximum point. This is so you do
not miss to start the hydraulic unit
1. Select the sub-menu "Sensor on/off calibrate" from the
"Settings" menu.
2. Scroll using the arrow keys and press OK when
"Calibrate pressure sensor for hydraulics" is shown.
3. Press OK again when the display shows CALIBRATE
MAX POINT.
4. Adjust the oil pressure reduction valve to 215 bar.
5. Press arrow up/down until the value for the oil pressure
is shown as 215 bar, i.e. the same value as on the
pressure gauge on the oil pressure reduction valve.
6. Press OK to execute calibration.
7. Press the down arrow to continue to the next part menu.
4.7 Calibrate potentiometer
This function is used when calibrating the zero positions
on the knobs for blade motion and trolley motion .
To calibrate the zero positions:
1. Scroll using the arrow keys and press OK when
"Calibrate potentiometers" is shown.
The display shows: CALIBRATE 0 0. The left-hand digit
refers to the blade motion and the right digit refers to the
trolley motion.
When the knobs are turned from the zero position the
zeros are shown and a number of >>>. The number of
arrows depends on how far the knobs are from the zero
positions.
1. Remove the knobs by unscrewing the screws located
on the side of each knob. Use an allen key.
2. Turn the shafts until only two zeros are shown on the
display.
3. Fit the knobs again.
4. Adjust the plastic washer.
5. Press OK.
6. Press the down arrow to continue to "Back to the menu".
5 Settings Smartbox
This sub-menu contains information about the hydraulic
unit and functions for setting of units and the PIN code.
The sub-menu consists of six part menus:
1. Husqvarna Smartbox version
2. AM (American) units
3. Radio ID
4. ID Hydraulic unit
5. PIN code
6. Change the PIN code
1. Husqvarna Smartbox version. The display shows the
version number, for example 2.0, for the software.
Press the down arrow to continue to the next part menu.
2. AM units. The display shows: AM units and ON or OFF.
When the function is ON American units are used in
the menu system.
Press the down arrow to continue to the next part menu.
3. Radio ID
In order to make radio contact with the remote control and
the hydraulic unit an ID number must be stated. The CAN
cable must be connected between the remote control and
the hydraulic unit to change the ID number.
Press OK when the display shows RADIOID 0 0.
The left-hand digit refers to the high byte and the right
digit refers to the low byte.
State, with the arrow keys, the high byte and press OK.
State, with the arrow keys, the low byte and press OK.
Press the down arrow to continue to the next part menu.
From the factory the ID number is the same as the machine
number. If the remote control or the hydraulic unit are
replaced or reprogrammed, an ID number must be stated.
As a suggestion, change to the hydraulic unit's ID number.
4. ID Hydraulic unit
The display shows the identity number for the hydraulic
unit. The identity number must be greater than 0.
Press the down arrow to continue to the next part menu.