Assembling/Installing
equipment
When the RC 455 is delivered there is only one 12 V DC
connector on the power cable. In order for the machine to
work, the end of the cable not fitted with a connector is
connected to the hydraulic unit's outgoing power cable.
When the machine has been transported to an
appropriate site and the hydraulic tool to be used is
correctly attached, the machine should be connected:
1. Turn on the ignition on the diesel-driven generating set
without starting the diesel engine.
2. Connect the incoming power cable from the diesel-
driven generating set to RC 455.
WARNING!
The RC 455 may only be connected to 12 V
DC voltage. If the machine is connected to
a higher voltage, the equipment can be
damaged and the operator can be seriously
injured.
3. Connect the remote control using the supplied Canbus
cable. Tighten the cable connector by hand.
When the machine is equipped with a radio, a radio
antenna can be connected instead of a Canbus cable.
This is screwed into the same socket as where the
Canbus cable should have been fitted.
12 - English
4. Check that the emergency stop on the remote control
is not activated. The display on the remote control now
shows "SMARTBOX CONNECT HOSE ASSEMBLY"
5. Connect the incoming hydraulic hoses from the diesel-
driven generating set to RC 455.
6. If CS2512 is to be used, connect the pressure
reduction block's female couplings to the male
couplings on RC 455.
7. Connect the hydraulic hoses from RC 455. There are
two types of hydraulic hoses between RC 455 and the
selected tool (WS 462, 463 or CS 2512):
On a wall saw in the WS 400 series, the four thin hoses
control the saw's motion motors, i.e. the saw's blade
motion and trolley motion. The two thick hoses drive
the blade.
When a wire saw CS 2512 is connected to the unit, the
two thin hoses control the tension on the magazine
arm while the two thick hoses drive the wire.
The hoses in the hose assembly marked with red discs
by the coupling are to be connected to the couplings
marked with similar discs.
8. When all hydraulic hoses are connected, confirm on
the remote control with "OK"
9. Start the diesel-driven generating set's engine and let it
idle.
10.The display now shows "SMARTBOX START MOTOR".
If the display does not show this, follow the instructions
shown on the display.
11.Check that all the equipment is ready for use.