19 Troubleshooting / Fault clearance

Fault
Working medium escapes
from leak detection hole*
Valve doesn't open or
doesn't open fully
Valve leaks downstream
(doesn't close or doesn't
close fully)
Valve leaks between
bonnet and valve body
Valve body connection to
piping leaks
Valve body leaks
Handwheel cannot be
turned
Proximity switch
continuously responds
* see chapter 20 "Sectional drawing and spare parts"
653, 654
Possible cause
Shut off diaphragm faulty
Bonnet faulty
Shut off diaphragm incorrectly
mounted
Stroke limiter is incorrectly set
With special version "K (MAG /
LOC)" locking device closed
Operating pressure too high
Foreign matter between shut off
diaphragm and valve body weir
Valve body weir leaking or
damaged
Shut off diaphragm faulty
Seal adjuster is incorrectly set
With special version "F (MAG /
LOC)" locking device closed
Shut off diaphragm incorrectly
mounted
Bolting between valve body and
bonnet loose
Shut off diaphragm faulty
Bonnet / valve body damaged
Incorrect installation
Bolting / threaded connections
loose
Sealing material faulty
Valve body faulty or corroded
Bonnet faulty
With special version "B (MAG /
LOC)" locking device closed
Threaded spindle seized
Wrong proximity switch used
Fault clearance
Check shut off diaphragm for damage, replace
diaphragm if necessary
Replace bonnet
Remove bonnet, check diaphragm mounting,
replace if necessary
Reset stroke limiter
Unlock locking device
Operate valve with operating pressure specified in
data sheet
Remove bonnet, remove foreign matter, check
diaphragm and valve body weir for damage and
replace if necessary
Check valve body weir for damage, if necessary
replace valve body
Check shut off diaphragm for damage, replace
diaphragm if necessary
Reset seal adjuster (see chapter 10.3)
Unlock locking device
Remove bonnet, check diaphragm mounting,
replace if necessary
Retighten bolting between valve body and bonnet
Check shut off diaphragm for damage, replace
diaphragm if necessary
Replace bonnet / valve body
Check installation of valve body in piping
Tighten bolting / threaded connections
Replace sealing material
Check valve body for damage, replace valve body if
necessary
Replace bonnet
Unlock locking device
Dependent on the operating conditions, regrease the
threaded spindle; replace bonnet if necessary.
See chapter 14.
Only use proximity switch that can be mounted flush
52 / 56