Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting The Pneumatic System En - Abicor Binzel BRS-LCi SPS Betriebsanleitung

Brennerreinigunngsstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 Operation
6.9 Connecting the pneumatic system
A compressed-air hose with a min. inner width of ø 8mm is required as a supply line. This is fastened to the
assembly stand's connection plate by a screw connection (not included). A shut-off valve in the supply line
is recommended. This allows the BRS-LCi PLC to be quickly and simply depressurized in order to carry out
any installation and maintenance work.
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance, servicing, assembly,
disassembly, and repair work:
• The BRS-LCi PLC torch cleaning station must remain without pressure until installation is complete.
NOTICE
• The DAV's cutting capacity depends on the operating pressure, the number of revolutions of the motor
Fig. 16
7 Operation
NOTICE
• As the BRS-LCi PLC torch cleaning station is integrated into a welding system, the operating
• Make sure that the BRS-LCi PLC is only operated with the protective cover supplied ex works.
1 Switch on the robot control system.
2 Start the welding process.
3 Stop the welding process.
EN - 22
WARNING
and the atomization of the anti-spatter fluid. Use a test run to determine the best settings.
Pneumatic motor
Clamping cylinder
closed
open
Z2
S2
8 mm
6 mm
Y2
4
2
14
12
14
12
1 3
5
Connecting the pneumatic system
instructions for the welding components, such as welding torch and robot mount, must be observed
during operation.
Stroke cylinder
down
up
S4
Z1
S1
6 mm
6 mm
Y1
4
2
14
12
14
12
5
1
3
BRS-LCi PLC
Pneumatic motor
6 mm
6 mm
6 mm
6 mm
Y4
4
2
14
12
14
12
5
1
3
Tank
Anti-spatter
fluid
min. 0.6 bar/PSI

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis