6 Putting into operation
6.8.2 Venturi valve (Venturi inductor)
1
4
1
5/2 directional valve
2
Anti-spatter fluid volume adjusting screw
Fig. 13
Venturi valve (Venturi inductor)
To adjust the injection volume, the system must be supplied with compressed air. To assess the function and
the injection volume, the solenoid valve Y4 (XS1, PIN2) must be open.
 6.9 Connecting the pneumatic system on page EN-22
The injection quantity can be set using the anti-spatter fluid volume adjusting screw (2).
The 5/2 directional valve (1) specifies the injection period via the robot control system.
Risk of crushing
Limbs can be drawn in and crushed by moving parts (reamer, clamping unit).
• Keep your hands away from moving parts.
Damage to the eyes
When injecting the anti-spatter fluid, spray mist can form that can damage the eyes.
• Wear safety goggles.
• Only adjust the anti-spatter fluid by opening the solenoid valve Y4.
1 If necessary, connect the siphon hose to the anti-spatter fluid bottle (4).
2 Open Y4.
3 Use the adjusting screw (2) to adjust the quantity of anti-spatter fluid.
4 Close Y4.
EN - 20
WARNING
WARNING
2
3
Venturi inductor
4
Anti-spatter fluid bottle
BRS-LCi PLC
3