1 - INSTRUCTIONS FOR INSTALLATION

1.1 Identifying the models
Gas solid top with electric oven
Solid top + 2 gas open burners with electric oven
1.2 Technical data
The technical data of these solid tops are indicated in the Tables
T4, T5, T5A and T6 (refer to the Enclosures).

2 - GENERAL INSTRUCTIONS

Read the instructions of this handbook carefully because they
supply important information on installation, use and maintenance
safety. Keep this handbook carefully for any further reference of the
various operators. The installation, transformation and maintenance
of this equipment must exclusively be carried out by qualified
installers or by proper companies complying with the safety rules in
force.
The Manufacturer declines any liability if these rules are not
complied with.
2.1 Installation
After unpacking, check that the equipment is intact. In case of any
doubt, do not operate this apparatus and call immediately a
professional engineer. Arrange the packing elements far from
children, because they can be dangerous. The equipment must
definitively be installed in the position it occupies in the kitchen,
preferably under an exhausting hood for a proper recirculation of air.
The equipment must be installed only in rooms with a good
ventilation. Any equipment of the type A must be installed only in
rooms with a good ventilation, according to the technical rules in
force. An optimum position may be under an exhausting hood that
intakes combustion gases and vapours. The installation of any
equipment of the type B11 must be carried out in such a way that
exhaust gases are sent to a proper system constructed according to
the standards in force. The connection stack is supplied separately.
Specify the type of installation crossing the proper square: A1 - B11
- B21, of the rating plate (included in the control board). This
equipment is not available in built-in version. The equipment must
be positioned at least 10 cm far from any wall surrounding it. In case
of fire-proofing, or thermally insulated walls, this distance can also
be reduced. The overall dimensions of the equipment are indicated
in the following pages.
2.2 Installing the connection stack (fig. 6)
Remove the grates of flue-gas exhaust from the stack of the
equipment. Remove the film protecting the adhesive strips of the 2
threaded plates "B" and make them adhere in the stack "A", as it is
shown in the fig. 6. The holes must coincide. Remove the back of
the stack "C". Position the stack "C" on the stack "A"; fasten them
with the screws "D". Apply the back of the stack "C" again.
2.3 Installation under exhausting hood (fig. 7)
When installing the equipment under an exhausting hood, mount the
connection stack (without draft switch) at such a height that the
distance between the stack end and the filter of the hood must be
included between 125 and 200 mm. This result can be obtained
through the following operations (fig. 7):
install the stack as it has been explained at the point 2.2; Insert the
moving element of the stack in its end, then shift it until the desired
height (between 125 and 200 mm) is reached. Fix this "telescopic"
section drilling 4 holes in the reference points marked on the 2 sides
SERIE 700
803132149
803132469
of the moving element, then fasten with the proper self-tapping
screws.
2.4 Installing the draft switch (fig. 8)
When required by the rules in force, the draft switch (supplied
separately) must be applied as follows:
install the stack following the instructions of the point 2.2; Apply the
draft switch to the stack. Fasten it with the 4 self-tapping screws.
Insert the exhaust pipe of proper diameter, for the connection to the
outside, in the sleeve of the draft switch.
2.5 Assembling
Remove the protection film from the outer surfaces of the apparatus.
Clean these surfaces from probable residual adhesive using a
proper solvent. Level the apparatus turning the proper adjustable
feet. As regards the assembling of the stack extension, refer to the
point 2.2. As regards the assembling of the draft switch (when
necessary), refer to the point 2.4.
2.6 Aligning the equipment (fig. 2)
Operate as follows: Remove the knobs and the control board of the
top. Arrange the apparatuses side by side and level at the same
height. Fasten the apparatuses with the proper screws, as shown in
the fig. 2.
2.7 Connection to the gas pipe network
Before connecting the equipment, consult the gas service company.
Insert a cutoff cock before the apparatus, in an easily accessible
position. Make sure that there are no leaks in pipe unions. If this
connection has to be carried out in the rear side of the top, remove
the respective plug and apply it air tightly onto the frontal
connection. Check whether the equipment is prearranged for the
feeding gas; if necessary, adapt the apparatus to the type of gas
supplied by the gas service, after reading the paragraph 3 carefully.
In Denmark, before connecting the equipment to the gas pipe
network, screw the nipple supplied with the apparatus, on the
feeding ramp.
2.8 Electrical connections
The equipment has been designed to operate at the voltage
indicated on the rating plate, with a tolerance of + 10%. Each
apparatus must be powered through a separate line properly sized.
The connection must be carried out on the terminal board where this
line arrives, through a flexible cable sheathed with rubber H05RN-F
and protected by a stiff plastic or metallic pipe. Special circuit
breakers of proper capacity, with a contact opening of at least 3
mm, as well as other protection devices against direct and indirect
contacts of alive parts and against fault currents to the ground, must
be connected according to the standards in force (maximum
allowable leakage current: 1 mA/kW).
2.9 Grounding and bonding of the equipment
Ground the equipment through the terminal marked with
terminal board where the line arrives. Moreover, connect the
metallic structure of any electric device to the terminal marked with
(bonding).