Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of The Welding Cables - CEA Rainbow 200 HF Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 32
Fig. A
4
3
2
1
Fig. B
FRONT PANEL (fig. B)
Pos. 1 "Weld mode" button: 2
STROKE, 4 STROKE, CYCLE,
SPOT-WELD.
Pos. 2 "Weld process" button: TIG
with HF arc strike, TIG with
"lift" type arc strike, ELEC-
TRODE (for basic electrode
welding with "arc force" and
"hot start" device). Cr-Ni
ELECTRODE (for welding
stainless steel with special
characteristics of having a
softer arc).
Pos. 3 Multi-purpose switch for pro-
gramming, parameter and weld
programme call up and stor-
age.
Pos. 4 Red led PRE-GAS function.
Pos. 5 Red led INITIAL CURRENT
function.
Pos. 6 Red led SLOPE UP function
Pos. 7 GREEN LED MAIN CURRENT
(l1) function
Pos. 8 RED LED 2nd LEVEL CUR-
RENT (I2) function, only works
with CYCLE function on.
Pos. 9 Red led BASIC CURRENT (Ib)
function - only work with
PULSE function on.
1
2
3
7
5
6
7
8
9
Pos. 10 Red led PEAK
Pos. 11 Red led SLOPE
Pos. 12 Red led FINAL
Pos. 13 POST GAS red led
Pos. 14 Red led PULSA-
Pos. 15 PULSATED TIG
Pos. 16 Digital display for
Pos. 17 Digital adjustment/
10 11 12
13
14
15
16
17
CURRENT (Ip)
function - only
works with PULSE
function on.
DOWN function.
CURRENT func-
tion.
function.
TION FRE-
QUENCY (f) func-
tion - only works
with PULSE func-
tion on.
and EASY PULSE
switch.
pre-setting and
visualizing all the
parameters. The
display also acts
as a digital amper-
ometer.
control for all weld
parameters.
15
Connection of the
welding cables
ELECTRODE WELDING (MMA)
4
With the machine disconnected from the
supply, connect the welding cables to
5
the out terminals (positive and negative)
of the welder, connecting them to the
gripper and the earth, with the correct
polarity provided for the type of elec-
6
trode to be used (Fig. C).
Choosing the indications supplied by the
electrode manufacturer, the welding
cables must be as short as possible,
close to one other, and positioned at
floor level or close to it.
TIG WELDING
• Connect the gas pipe at the rear of the
machine to the Argon gas cylinder
then open it (pos. 5, fig. D).
• When the machine is switched off
connect the earth cable to the quick
coupling marked + (positive) (pos. 3,
fig. D).
• Connect the relative earth clamp to
the piece to be welded or nearby
ensuring that the area is free from
rust, paint, grease, ecc..
• When the machine is switched off
connect the earth cable to the quick
coupling marked - (negative) (pos. 1,
fig. D).
• Connect the torch gas tube to the con-
nection (pos. 4, fig. D).
• Insert the torch button connector in
the 6 poles holder (pos. 2, fig. D).
Fig. C